me

Motion-Robust Super-resolution Magnetic Resonance Imaging

Tutorial at ISBI2013

RELATED PUBLICATIONS



CRL Publications

A. Gholipour, J. A. Estroff, S. K. Warfield,  Robust super-resolution volume reconstruction from slice acquisitions: application to fetal brain MRI,  IEEE Trans Med Imaging,  29(10),  2010,  1739-58
bibtex doi
Benoit Scherrer, Ali Gholipour, Simon K. Warfield,  Super-resolution reconstruction to increase the spatial resolution of diffusion weighted images from orthogonal anisotropic acquisitions,  Med Imag Analysis,  16(7),  2012,  1465-1476
bibtex doi
Elsevier/MEDIA Best Paper Award 2012
O. Afacan, W. S. Hoge, F. Janoos, D. H. Brooks, I. A. Morocz,  Rapid full-brain fMRI with an accelerated multi shot 3D EPI sequence using both UNFOLD and GRAPPA,  Magn Reson Med,  67(5),  2012,  1266-74
bibtex doi
A. Gholipour, M. Polak, A. van der Kouwe, E. Nevo, S. K. Warfield,  Motion-robust MRI through real-time motion tracking and retrospective super-resolution volume reconstruction,  Conf Proc IEEE Eng Med Biol Soc,  2011,  2011,  5722-5
bibtex doi
Benoit Scherrer, Simon K Warfield,  Retrospective local artefact detection in diffusion-weighted images using the random sample consensus (RANSAC) paradigm,  Proc. of the 9th IEEE International Symposium on Biomedical Imaging (ISBI),  Barcelona, Spain,  2012,  546-549
bibtex doi
(EN, Draft version)
Benoit Scherrer, Ali Gholipour, Simon K Warfield,  Super-Resolution Reconstruction of Diffusion-Weighted Images from Distortion Compensated Orthogonal Anisotropic Acquisitions,  Proc. of the 12th IEEE Workshop on Mathematical Methods in Biomedical Image Analysis (MMBIA),  Breckenridge, USA,  2012,  249-256
bibtex doi
Benoit Scherrer, Ali Gholipour, Simon K Warfield,  Super-Resolution in Diffusion-Weighted Imaging,  Proc. of the 14th International Conference on Medical Image Computing and Computer Assisted Intervention (MICCAI),  14(2),  Toronto, Canada,  2011,  124-132
bibtex doi
Ali Gholipour, Nasser Kehtarnavaz, Benoit Scherrer, Simon K Warfield,  On the Accuracy of Unwarping Techniques for the Correction of Susceptibility-Induced Geometric Distortion in Magnetic Resonance Echo-Planar Images,  Proc. of the 33rd Annual International IEEE EMBS Conference,  Boston, USA,  2011
bibtex doi
A. Gholipour, M. Polak, A. van der Kouwe, E. Nevo, S.K. Warfield,   Motion-robust MRI through real-time motion tracking and retrospective super-resolution volume reconstruction ,   Conf Proc IEEE Eng Med Biol Soc.,  2011,  5722-5725
bibtex doi
A. Gholipour, J.A. Estroff, M. Sahin, S.P. Prabhu, S.K. Warfield,  Maximum A Posteriori Estimation of Isotropic High-Resolution Volumetric MRI from Orthogonal Thick-Slice Scans,  Med Image Comput Comput Assist Interv.,  6362,  2010,  109-116
bibtex doi
Benoit Scherrer, Ali Gholipour, Simon K Warfield,  Increasing the resolution of diffusion-weighted MRI with distortion compensated orthogonal acquisitions and super-resolution reconstruction,  Proc. the 20th International Symposium on Magnetic Resonance in Medicine (ISMRM),  Melbourne, Australia,  2012
bibtex
ISMRM Magna Cum Laude Merit Award

Other

M. Aggarwal, J. Zhang, O. Pletnikova, B. Crain, J. Troncoso, S. Mori,  Feasibility of creating a high-resolution 3D diffusion tensor imaging based atlas of the human brainstem: A case study at 11.7T,  Neuroimage,  2013
bibtex doi
L. V. Blomster, G. J. Cowin, N. D. Kurniawan, M. J. Ruitenberg,  Detection of endogenous iron deposits in the injured mouse spinal cord through high-resolution ex vivo and in vivo MRI,  NMR Biomed,  26(2),  2013,  141-50
bibtex doi
G. Chen, F. Wang, J. C. Gore, A. W. Roe,  Layer-specific BOLD activation in awake monkey V1 revealed by ultra-high spatial resolution functional magnetic resonance imaging,  Neuroimage,  64,  2013,  147-55
bibtex doi
M. Herbst, J. Maclaren, C. Lovell-Smith, R. Sostheim, K. Egger, A. Harloff, J. Korvink, J. Hennig, M. Zaitsev,  Reproduction of motion artifacts for performance analysis of prospective motion correction in MRI,  Magn Reson Med,  2013
bibtex doi
H. K. Jeong, J. C. Gore, A. W. Anderson,  High-resolution human diffusion tensor imaging using 2-D navigated multishot SENSE EPI at 7 T,  Magn Reson Med,  69(3),  2013,  793-802
bibtex doi
F. Lusebrink, A. Wollrab, O. Speck,  Cortical thickness determination of the human brain using high resolution 3T and 7T MRI data,  Neuroimage,  70,  2013,  122-31
bibtex doi
J. Muraskin, M. B. Ooi, R. I. Goldman, S. Krueger, W. J. Thomas, P. Sajda, T. R. Brown,  Prospective active marker motion correction improves statistical power in BOLD fMRI,  Neuroimage,  68,  2013,  154-61
bibtex doi
M. B. Ooi, J. Muraskin, X. Zou, W. J. Thomas, S. Krueger, M. Aksoy, R. Bammer, T. R. Brown,  Combined prospective and retrospective correction to reduce motion-induced image misalignment and geometric distortions in EPI,  Magn Reson Med,  69(3),  2013,  803-11
bibtex doi
D. H. Poot, B. Jeurissen, Y. Bastiaensen, J. Veraart, W. Van Hecke, P. M. Parizel, J. Sijbers,  Super-resolution for multislice diffusion tensor imaging,  Magn Reson Med,  69(1),  2013,  103-13
bibtex doi
L. Qin, E. J. Schmidt, Z. T. Tse, J. Santos, W. S. Hoge, C. Tempany-Afdhal, K. Butts-Pauly, C. L. Dumoulin,  Prospective motion correction using tracking coils,  Magn Reson Med,  69(3),  2013,  749-59
bibtex doi
A. K. Seehaus, A. Roebroeck, O. Chiry, D. S. Kim, I. Ronen, H. Bratzke, R. Goebel, R. A. Galuske,  Histological validation of DW-MRI tractography in human postmortem tissue,  Cereb Cortex,  23(2),  2013,  442-50
bibtex doi
Y. Y. Shih, Y. Y. Chen, H. Y. Lai, Y. C. Kao, B. C. Shyu, T. Q. Duong,  Ultra high-resolution fMRI and electrophysiology of the rat primary somatosensory cortex,  Neuroimage,  73C,  2013,  113-120
bibtex doi
E. Takahashi, J. W. Song, R. D. Folkerth, P. E. Grant, J. D. Schmahmann,  Detection of postmortem human cerebellar cortex and white matter pathways using high angular resolution diffusion tractography: A feasibility study,  Neuroimage,  68,  2013,  105-11
bibtex doi
E Oubel, M Koob, C Studholme, J-L Dietemann, F Rousseau,  Reconstruction of Scattered Data in Fetal Diffusion MRI,  Med Imag Analysis,  16(1),  2012,  28-37
bibtex doi
I. Aganj, C. Lenglet, E. Yacoub, G. Sapiro, N. Harel,  A 3D wavelet fusion approach for the reconstruction of isotropic-resolution MR images from orthogonal anisotropic-resolution scans,  Magn Reson Med,  67(4),  2012,  1167-72
bibtex doi
D. Barazany, Y. Assaf,  Visualization of cortical lamination patterns with magnetic resonance imaging,  Cereb Cortex,  22(9),  2012,  2016-23
bibtex doi
F. Calamante, J. D. Tournier, N. D. Kurniawan, Z. Yang, E. Gyengesi, G. J. Galloway, D. C. Reutens, A. Connelly,  Super-resolution track-density imaging studies of mouse brain: comparison to histology,  Neuroimage,  59(1),  2012,  286-96
bibtex doi
G. Chen, F. Wang, J. C. Gore, A. W. Roe,  Identification of cortical lamination in awake monkeys by high resolution magnetic resonance imaging,  Neuroimage,  59(4),  2012,  3441-9
bibtex doi
J. J. Entis, P. Doerga, L. F. Barrett, B. C. Dickerson,  A reliable protocol for the manual segmentation of the human amygdala and its subregions using ultra-high resolution MRI,  Neuroimage,  60(2),  2012,  1226-35
bibtex doi
M. S. Hansen, T. S. Sorensen, A. E. Arai, P. Kellman,  Retrospective reconstruction of high temporal resolution cine images from real-time MRI using iterative motion correction,  Magn Reson Med,  68(3),  2012,  741-50
bibtex doi
N. Harel,  Ultra high resolution fMRI at ultra-high field,  Neuroimage,  62(2),  2012,  1024-8
bibtex doi
S. J. Holdsworth, M. Aksoy, R. D. Newbould, K. Yeom, A. T. Van, M. B. Ooi, P. D. Barnes, R. Bammer, S. Skare,  Diffusion tensor imaging (DTI) with retrospective motion correction for large-scale pediatric imaging,  J Magn Reson Imaging,  36(4),  2012,  961-71
bibtex doi
T. Kober, R. Gruetter, G. Krueger,  Prospective and retrospective motion correction in diffusion magnetic resonance imaging of the human brain,  Neuroimage,  59(1),  2012,  389-98
bibtex doi
M. Kuklisova-Murgasova, G. Quaghebeur, M. A. Rutherford, J. V. Hajnal, J. A. Schnabel,  Reconstruction of fetal brain MRI with intensity matching and complete outlier removal,  Med Image Anal,  16(8),  2012,  1550-64
bibtex doi
C. Lenglet, A. Abosch, E. Yacoub, F. De Martino, G. Sapiro, N. Harel,  Comprehensive in vivo mapping of the human basal ganglia and thalamic connectome in individuals using 7T MRI,  PLoS One,  7(1),  2012,  e29153
bibtex doi
L. A. Massey, M. A. Miranda, L. Zrinzo, O. Al-Helli, H. G. Parkes, J. S. Thornton, P. W. So, M. J. White, L. Mancini, C. Strand, J. L. Holton, M. I. Hariz, A. J. Lees, T. Revesz, T. A. Yousry,  High resolution MR anatomy of the subthalamic nucleus: imaging at 9.4 T with histological validation,  Neuroimage,  59(3),  2012,  2035-44
bibtex doi
M. H. Moghari, S. Roujol, R. H. Chan, S. N. Hong, N. Bello, M. Henningsson, L. H. Ngo, B. Goddu, L. Goepfert, K. V. Kissinger, W. J. Manning, R. Nezafat,  Free-breathing 3D cardiac MRI using iterative image-based respiratory motion correction,  Magn Reson Med,  2012
bibtex doi
S. Nielles-Vallespin, C. Mekkaoui, P. Gatehouse, T. G. Reese, J. Keegan, P. F. Ferreira, S. Collins, P. Speier, T. Feiweier, R. de Silva, M. P. Jackowski, D. J. Pennell, D. E. Sosnovik, D. Firmin,  In vivo diffusion tensor MRI of the human heart: Reproducibility of breath-hold and navigator-based approaches,  Magn Reson Med,  2012
bibtex doi
E. Plenge, D. H. Poot, M. Bernsen, G. Kotek, G. Houston, P. Wielopolski, L. van der Weerd, W. J. Niessen, E. Meijering,  Super-resolution methods in MRI: can they improve the trade-off between resolution, signal-to-noise ratio, and acquisition time?,  Magn Reson Med,  68(6),  2012,  1983-93
bibtex doi
J. D. Power, K. A. Barnes, A. Z. Snyder, B. L. Schlaggar, S. E. Petersen,  Spurious but systematic correlations in functional connectivity MRI networks arise from subject motion,  Neuroimage,  59(3),  2012,  2142-54
bibtex doi
B. Scherrer, A. Gholipour, S. K. Warfield,  Super-resolution reconstruction to increase the spatial resolution of diffusion weighted images from orthogonal anisotropic acquisitions,  Med Image Anal,  16(7),  2012,  1465-76
bibtex doi
M. D. Tisdall, A. T. Hess, M. Reuter, E. M. Meintjes, B. Fischl, A. J. van der Kouwe,  Volumetric navigators for prospective motion correction and selective reacquisition in neuroanatomical MRI,  Magn Reson Med,  68(2),  2012,  389-99
bibtex doi
K. R. Van Dijk, M. R. Sabuncu, R. L. Buckner,  The influence of head motion on intrinsic functional connectivity MRI,  Neuroimage,  59(1),  2012,  431-8
bibtex doi
Eric Van Reeth, Ivan WK Tham, Cher Heng Tan, Chueh Loo Poh,  Super‐resolution in magnetic resonance imaging: A review,  Concepts in Magnetic Resonance Part A,  40(6),  2012,  306-325
bibtex
N. M. van Strien, M. Wideroe, W. D. van de Berg, H. B. Uylings,  Imaging hippocampal subregions with in vivo MRI: advances and limitations,  Nat Rev Neurosci,  13(1),  2012,  70
bibtex doi
C. Votino, J. Jani, M. Verhoye, B. Bessieres, Y. Fierens, V. Segers, A. Vorsselmans, X. Kang, T. Cos, W. Foulon, J. De Mey, M. Cannie,  Postmortem examination of human fetal hearts at or below 20 weeks' gestation: a comparison of high-field MRI at 9.4 T with lower-field MRI magnets and stereomicroscopic autopsy,  Ultrasound Obstet Gynecol,  40(4),  2012,  437-44
bibtex doi
J. Woo, E. Z. Murano, M. Stone, J. L. Prince,  Reconstruction of high-resolution tongue volumes from MRI,  IEEE Trans Biomed Eng,  59(12),  2012,  3511-24
bibtex doi
M. Aksoy, C. Forman, M. Straka, S. Skare, S. Holdsworth, J. Hornegger, R. Bammer,  Real-time optical motion correction for diffusion tensor imaging,  Magn Reson Med,  66(2),  2011,  366-78
bibtex doi
M. Axer, K. Amunts, D. Grassel, C. Palm, J. Dammers, H. Axer, U. Pietrzyk, K. Zilles,  A novel approach to the human connectome: ultra-high resolution mapping of fiber tracts in the brain,  Neuroimage,  54(2),  2011,  1091-101
bibtex doi
J. K. Barral, J. M. Santos, E. J. Damrose, N. J. Fischbein, D. G. Nishimura,  Real-time motion correction for high-resolution larynx imaging,  Magn Reson Med,  66(1),  2011,  174-9
bibtex doi
T. Benner, A. J. van der Kouwe, A. G. Sorensen,  Diffusion imaging with prospective motion correction and reacquisition,  Magn Reson Med,  66(1),  2011,  154-67
bibtex doi
K. Cheng,  Recent progress in high-resolution functional MRI,  Curr Opin Neurol,  24(4),  2011,  401-8
bibtex doi
C. F. Ferris, B. Smerkers, P. Kulkarni, M. Caffrey, O. Afacan, S. Toddes, T. Stolberg, M. Febo,  Functional magnetic resonance imaging in awake animals,  Rev Neurosci,  22(6),  2011,  665-74
bibtex doi
M. Filipovic, P. A. Vuissoz, A. Codreanu, M. Claudon, J. Felblinger,  Motion compensated generalized reconstruction for free-breathing dynamic contrast-enhanced MRI,  Magn Reson Med,  65(3),  2011,  812-22
bibtex doi
C. Forman, M. Aksoy, J. Hornegger, R. Bammer,  Self-encoded marker for optical prospective head motion correction in MRI,  Med Image Anal,  15(5),  2011,  708-19
bibtex doi
P. Hu, S. Hong, M. H. Moghari, B. Goddu, L. Goepfert, K. V. Kissinger, T. H. Hauser, W. J. Manning, R. Nezafat,  Motion correction using coil arrays (MOCCA) for free-breathing cardiac cine MRI,  Magn Reson Med,  66(2),  2011,  467-75
bibtex doi
J. Maclaren, K. J. Lee, C. Luengviriya, O. Speck, M. Zaitsev,  Combined prospective and retrospective motion correction to relax navigator requirements,  Magn Reson Med,  65(6),  2011,  1724-32
bibtex doi
K. L. Miller, C. J. Stagg, G. Douaud, S. Jbabdi, S. M. Smith, T. E. Behrens, M. Jenkinson, S. A. Chance, M. M. Esiri, N. L. Voets, N. Jenkinson, T. Z. Aziz, M. R. Turner, H. Johansen-Berg, J. A. McNab,  Diffusion imaging of whole, post-mortem human brains on a clinical MRI scanner,  Neuroimage,  57(1),  2011,  167-81
bibtex doi
M. H. Moghari, M. Akcakaya, A. O'Connor, T. A. Basha, M. Casanova, D. Stanton, L. Goepfert, K. V. Kissinger, B. Goddu, M. L. Chuang, V. Tarokh, W. J. Manning, R. Nezafat,  Compressed-sensing motion compensation (CosMo): a joint prospective-retrospective respiratory navigator for coronary MRI,  Magn Reson Med,  66(6),  2011,  1674-81
bibtex doi
M. B. Ooi, S. Krueger, J. Muraskin, W. J. Thomas, T. R. Brown,  Echo-planar imaging with prospective slice-by-slice motion correction using active markers,  Magn Reson Med,  66(1),  2011,  73-81
bibtex doi
A. Roche,  A four-dimensional registration algorithm with application to joint correction of motion and slice timing in fMRI,  IEEE Trans Med Imaging,  30(8),  2011,  1546-54
bibtex doi
B. Scherrer, A. Gholipour, S. K. Warfield,  Super-resolution in diffusion-weighted imaging,  Med Image Comput Comput Assist Interv,  14(Pt 2),  2011,  124-32
bibtex
Q. M. Tieng, G. J. Cowin, D. C. Reutens, G. J. Galloway, V. Vegh,  MRI resolution enhancement: how useful are shifted images obtained by changing the demodulation frequency?,  Magn Reson Med,  65(3),  2011,  664-72
bibtex doi
M. Uecker, T. J. Sumpf, J. Frahm,  Reply to: MRI resolution enhancement: how useful are shifted images obtained by changing the demodulation frequency?,  Magn Reson Med,  66(6),  2011,  1511-2; author reply 1513-4
bibtex doi
M. Aksoy, S. Skare, S. Holdsworth, R. Bammer,  Effects of motion and b-matrix correction for high resolution DTI with short-axis PROPELLER-EPI,  NMR Biomed,  23(7),  2010,  794-802
bibtex doi
A. K. Attili, A. Schuster, E. Nagel, J. H. Reiber, R. J. van der Geest,  Quantification in cardiac MRI: advances in image acquisition and processing,  Int J Cardiovasc Imaging,  26 Suppl 1,  2010,  27-40
bibtex doi
T. T. Brown, J. M. Kuperman, M. Erhart, N. S. White, J. C. Roddey, A. Shankaranarayanan, E. T. Han, D. Rettmann, A. M. Dale,  Prospective motion correction of high-resolution magnetic resonance imaging data in children,  Neuroimage,  53(1),  2010,  139-45
bibtex doi
K. Kim, P. A. Habas, F. Rousseau, O. A. Glenn, A. J. Barkovich, C. Studholme,  Intersection based motion correction of multislice MRI for 3-D in utero fetal brain image formation,  IEEE Trans Med Imaging,  29(1),  2010,  146-58
bibtex doi
P. Kochunov, C. Castro, D. Davis, D. Dudley, J. Brewer, Y. Zhang, C. D. Kroenke, D. Purdy, P. T. Fox, C. Simerly, G. Schatten,  Mapping primary gyrogenesis during fetal development in primate brains: high-resolution in utero structural MRI of fetal brain development in pregnant baboons,  Front Neurosci,  4,  2010,  20
bibtex doi
R. La Joie, M. Fouquet, F. Mezenge, B. Landeau, N. Villain, K. Mevel, A. Pelerin, F. Eustache, B. Desgranges, G. Chetelat,  Differential effect of age on hippocampal subfields assessed using a new high-resolution 3T MR sequence,  Neuroimage,  53(2),  2010,  506-14
bibtex doi
W. Lin, F. Huang, P. Bornert, Y. Li, A. Reykowski,  Motion correction using an enhanced floating navigator and GRAPPA operations,  Magn Reson Med,  63(2),  2010,  339-48
bibtex doi
J. Maclaren, O. Speck, D. Stucht, P. Schulze, J. Hennig, M. Zaitsev,  Navigator accuracy requirements for prospective motion correction,  Magn Reson Med,  63(1),  2010,  162-70
bibtex doi
J. V. Manjon, P. Coupe, A. Buades, V. Fonov, D. Louis Collins, M. Robles,  Non-local MRI upsampling,  Med Image Anal,  14(6),  2010,  784-92
bibtex doi
D. Pitt, A. Boster, W. Pei, E. Wohleb, A. Jasne, C. R. Zachariah, K. Rammohan, M. V. Knopp, P. Schmalbrock,  Imaging cortical lesions in multiple sclerosis with ultra-high-field magnetic resonance imaging,  Arch Neurol,  67(7),  2010,  812-8
bibtex doi
D. H. Poot, V. Van Meir, J. Sijbers,  General and efficient super-resolution method for multi-slice MRI,  Med Image Comput Comput Assist Interv,  13(Pt 1),  2010,  615-22
bibtex
A. A. Samsonov, J. Velikina, Y. Jung, E. G. Kholmovski, C. R. Johnson, W. F. Block,  POCS-enhanced correction of motion artifacts in parallel MRI,  Magn Reson Med,  63(4),  2010,  1104-10
bibtex doi
K. Schmierer, H. G. Parkes, P. W. So, S. F. An, S. Brandner, R. J. Ordidge, T. A. Yousry, D. H. Miller,  High field (9.4 Tesla) magnetic resonance imaging of cortical grey matter lesions in multiple sclerosis,  Brain,  133(Pt 3),  2010,  858-67
bibtex doi
N. White, C. Roddey, A. Shankaranarayanan, E. Han, D. Rettmann, J. Santos, J. Kuperman, A. Dale,  PROMO: Real-time prospective motion correction in MRI using image-based tracking,  Magn Reson Med,  63(1),  2010,  91-105
bibtex doi
Hayit Greenspan,  Super-resolution in medical imaging,  The Computer Journal,  52(1),  2009,  43-63
bibtex
S. Jiang, H. Xue, S. Counsell, M. Anjari, J. Allsop, M. Rutherford, D. Rueckert, J. V. Hajnal,  Diffusion tensor imaging (DTI) of the brain in moving subjects: application to in-utero fetal and ex-utero studies,  Magn Reson Med,  62(3),  2009,  645-55
bibtex doi
D. C. Karampinos, A. T. Van, W. C. Olivero, J. G. Georgiadis, B. P. Sutton,  High-resolution diffusion tensor imaging of the human pons with a reduced field-of-view, multishot, variable-density, spiral acquisition at 3 T,  Magn Reson Med,  62(4),  2009,  1007-16
bibtex doi
P. Kellman, C. Chefd'hotel, C. H. Lorenz, C. Mancini, A. E. Arai, E. R. McVeigh,  High spatial and temporal resolution cardiac cine MRI from retrospective reconstruction of data acquired in real time using motion correction and resorting,  Magn Reson Med,  62(6),  2009,  1557-64
bibtex doi
X. Liu, T. Zhu, T. Gu, J. Zhong,  A practical approach to in vivo high-resolution diffusion tensor imaging of rhesus monkeys on a 3-T human scanner,  Magn Reson Imaging,  27(3),  2009,  335-46
bibtex doi
J. A. McNab, S. Jbabdi, S. C. Deoni, G. Douaud, T. E. Behrens, K. L. Miller,  High resolution diffusion-weighted imaging in fixed human brain using diffusion-weighted steady state free precession,  Neuroimage,  46(3),  2009,  775-85
bibtex doi
R. Z. Shilling, T. Q. Robbie, T. Bailloeul, K. Mewes, R. M. Mersereau, M. E. Brummer,  A super-resolution framework for 3-D high-resolution and high-contrast imaging using 2-D multislice MRI,  IEEE Trans Med Imaging,  28(5),  2009,  633-44
bibtex doi
A. A. Tamhane, K. Arfanakis,  Motion correction in periodically-rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) and turboprop MRI,  Magn Reson Med,  62(1),  2009,  174-82
bibtex doi
S. Thayyil, J. O. Cleary, N. J. Sebire, R. J. Scott, K. Chong, R. Gunny, C. M. Owens, O. E. Olsen, A. C. Offiah, H. G. Parks, L. S. Chitty, A. N. Price, T. A. Yousry, N. J. Robertson, M. F. Lythgoe, A. M. Taylor,  Post-mortem examination of human fetuses: a comparison of whole-body high-field MRI at 9.4 T with conventional MRI and invasive autopsy,  Lancet,  374(9688),  2009,  467-75
bibtex doi
P. A. Yushkevich, B. B. Avants, J. Pluta, S. Das, D. Minkoff, D. Mechanic-Hamilton, S. Glynn, S. Pickup, W. Liu, J. C. Gee, M. Grossman, J. A. Detre,  A high-resolution computational atlas of the human hippocampus from postmortem magnetic resonance imaging at 9.4 T,  Neuroimage,  44(2),  2009,  385-98
bibtex doi
N. R. Zwart, J. G. Pipe,  Motion corrected intracranial MRA using PROPELLER with RF quadratic encoding,  Magn Reson Med,  61(6),  2009,  1405-14
bibtex doi
A. Roebroeck, R. Galuske, E. Formisano, O. Chiry, H. Bratzke, I. Ronen, D. S. Kim, R. Goebel,  High-resolution diffusion tensor imaging and tractography of the human optic chiasm at 9.4 T,  Neuroimage,  39(1),  2008,  157-68
bibtex doi
R. Bammer, M. Aksoy, C. Liu,  Augmented generalized SENSE reconstruction to correct for rigid body motion,  Magn Reson Med,  57(1),  2007,  90-102
bibtex doi
A. W. Dowsey, J. Keegan, M. Lerotic, S. Thom, D. Firmin, G. Z. Yang,  Motion-compensated MR valve imaging with COMB tag tracking and super-resolution enhancement,  Med Image Anal,  11(5),  2007,  478-91
bibtex doi
E. Carmi, S. Liu, N. Alon, A. Fiat, D. Fiat,  Resolution enhancement in MRI,  Magn Reson Imaging,  24(2),  2006,  133-54
bibtex doi
J. G. Pipe, N. Zwart,  Turboprop: improved PROPELLER imaging,  Magn Reson Med,  55(2),  2006,  380-5
bibtex doi
F. Rousseau, O. A. Glenn, B. Iordanova, C. Rodriguez-Carranza, D. B. Vigneron, J. A. Barkovich, C. Studholme,  Registration-based approach for reconstruction of high-resolution in utero fetal MR brain images,  Acad Radiol,  13(9),  2006,  1072-81
bibtex doi
O. Speck, J. Hennig, M. Zaitsev,  Prospective real-time slice-by-slice motion correction for fMRI in freely moving subjects,  MAGMA,  19(2),  2006,  55-61
bibtex doi
A. J. van der Kouwe, T. Benner, A. M. Dale,  Real-time rigid body motion correction and shimming using cloverleaf navigators,  Magn Reson Med,  56(5),  2006,  1019-32
bibtex doi
M. Zaitsev, C. Dold, G. Sakas, J. Hennig, O. Speck,  Magnetic resonance imaging of freely moving objects: prospective real-time motion correction using an external optical motion tracking system,  Neuroimage,  31(3),  2006,  1038-50
bibtex doi
C. Dold, M. Zaitsev, O. Speck, E. A. Firle, J. Hennig, G. Sakas,  Prospective head motion compensation for MRI by updating the gradients and radio frequency during data acquisition,  Med Image Comput Comput Assist Interv,  8(Pt 1),  2005,  482-9
bibtex
L. Filidoro, O. Dietrich, J. Weber, E. Rauch, T. Oerther, M. Wick, M. F. Reiser, C. Glaser,  High-resolution diffusion tensor imaging of human patellar cartilage: feasibility and preliminary findings,  Magn Reson Med,  53(5),  2005,  993-8
bibtex doi
F. N. Wang, T. Y. Huang, F. H. Lin, T. C. Chuang, N. K. Chen, H. W. Chung, C. Y. Chen, K. K. Kwong,  PROPELLER EPI: an MRI technique suitable for diffusion tensor imaging at high field strength with reduced geometric distortions,  Magn Reson Med,  54(5),  2005,  1232-40
bibtex doi
K. P. Forbes, J. G. Pipe, J. P. Karis, V. Farthing, J. E. Heiserman,  Brain imaging in the unsedated pediatric patient: comparison of periodically rotated overlapping parallel lines with enhanced reconstruction and single-shot fast spin-echo sequences,  AJNR Am J Neuroradiol,  24(5),  2003,  794-8
bibtex
D. Manke, K. Nehrke, P. Bornert,  Novel prospective respiratory motion correction approach for free-breathing coronary MR angiography using a patient-adapted affine motion model,  Magn Reson Med,  50(1),  2003,  122-31
bibtex doi
X. Golay, H. Jiang, P. C. van Zijl, S. Mori,  High-resolution isotropic 3D diffusion tensor imaging of the human brain,  Magn Reson Med,  47(5),  2002,  837-43
bibtex doi
J. G. Pipe, V. G. Farthing, K. P. Forbes,  Multishot diffusion-weighted FSE using PROPELLER MRI,  Magn Reson Med,  47(1),  2002,  42-52
bibtex doi
E. B. Welch, A. Manduca, R. C. Grimm, H. A. Ward, C. R. Jack,  Spherical navigator echoes for full 3D rigid body motion measurement in MRI,  Magn Reson Med,  47(1),  2002,  32-41
bibtex doi
S. Peled, Y. Yeshurun,  Superresolution in MRI: application to human white matter fiber tract visualization by diffusion tensor imaging,  Magn Reson Med,  45(1),  2001,  29-35
bibtex doi
S. Thesen, O. Heid, E. Mueller, L. R. Schad,  Prospective acquisition correction for head motion with image-based tracking for real-time fMRI,  Magn Reson Med,  44(3),  2000,  457-65
bibtex doi
H. A. Ward, S. J. Riederer, R. C. Grimm, R. L. Ehman, J. P. Felmlee, C. R. Jack,  Prospective multiaxial motion correction for fMRI,  Magn Reson Med,  43(3),  2000,  459-69
bibtex doi
J. G. Pipe,  Motion correction with PROPELLER MRI: application to head motion and free-breathing cardiac imaging,  Magn Reson Med,  42(5),  1999,  963-9
bibtex doi
S. Mori, P. C. van Zijl,  A motion correction scheme by twin-echo navigation for diffusion-weighted magnetic resonance imaging with multiple RF echo acquisition,  Magn Reson Med,  40(4),  1998,  511-6
bibtex
Z. W. Fu, Y. Wang, R. C. Grimm, P. J. Rossman, J. P. Felmlee, S. J. Riederer, R. L. Ehman,  Orbital navigator echoes for motion measurements in magnetic resonance imaging,  Magn Reson Med,  34(5),  1995,  746-53
bibtex
R. J. Ordidge, J. A. Helpern, Z. X. Qing, R. A. Knight, V. Nagesh,  Correction of motional artifacts in diffusion-weighted MR images using navigator echoes,  Magn Reson Imaging,  12(3),  1994,  455-60
bibtex
M Irani, S Peleg,  Motion Analysis for Image Enhancement : Resolution , Occlusion , and Transparency,  Journal of Visual Communication and Image Representation,  4(4),  1993,  324-335
bibtex doi